What was found
FWD MAIN CABIN FLOORBEAM -Y1732 FRAME 20 STR 23RH HAS CORROSION JF040. REMOVED CORROSION ON FWD MAIN CABIN FLOORBEAM WEB AT -Y1732 FRAME 20 STR 23 IAW A320 SRM 51-74-00, EVALUATED AREA ORGINAL THICKNESS 0.063" REMAINING THICKNESS 0.020" 2.0" X 1.5" AREA, FOUND TO BE OUT OF LIMITS IAW A320 SRM 53-11-12, REMOVED DAMAGED FLOOR BEAM WEB AND REPLACED WITH NEW FLOOR BEAM WEB P/N D5311278520301 PO# F$2109925 IAW A320 SRM 51-42-11. (LP# 2067551)