What was found
D INSP;ERA557424;3263 PERFORM ER/A 557424-14 SECTION I AT OR BEFORE 33400 FC FROM THE INSTALLATION DATE OF THE REPAIR ON 24- FEB-2016. AD 2016-12-04 REQUIRED INSPECTION; NO DEVIATIONS OR SUBSTITUTIONS. PERFORMED ULTRASONIC INSPECTION OF REPAIR #1 LOC. AT FR 2 AND 22 INCHES BELOW OF LH SIDE STRINGER PER A320 NTM 51-10-15-270-801- A-01 AND NO CRACK INDICATION FOUND. TOOL USED EDDY CURRENT FLAW DETECTOR P/N NORTE 500D; S/N N500X12101U102020 DUE DATE 01 JUN 22 AS PER E/RA 557424-14AD REV. ORIGINAL SECTION I. JOB COMPLETE. (LP# 0026659)