What was found
AFT CARGO. FLOOR BOARD SUPPORT/FORMER CORRODED AT STA 973 STRINGERS 29 AND 30 ATTACH POINTS, 6 INCHES FWD OF ANTENNA DOUBLER. (M) FLOOR BOARD SUPPORT/FORMER AT STA 973 STRINGERS 29 AND 30 ATTACH POINTS, 6 INCHES FWD OF ANTENNA DOUBLER FOUND CRACK, FOUND TO BE 100% OUT OF LIMITS PER B717 SRM 53-00-00-1A 3. REPAIRED AFT CARGO. FLOOR BOARD SUPPORT ANGLE AT STA 973 STRINGERS 29 AND 30 ATTACH POINTS, 6 INCHES FWD OF ANTENNA DOUBLER PER B717 SRM 51-70-05-2R 5. OK CIC 8. APPLIED CIC ON REPAIR AREA PER PS 900-2 NO. 09 9. CORROSION LEVEL: 2. (LP #2074161)