What was found
FAA STAGE III APPROVAL REQUIRES INITIAL AND RECURRING GENERAL VISUAL INSPECTIONS THAT BEGIN AND ARE REPEATED EVERY C-CHECK OR 24 MONTHS WHICHEVER OCCURS FIRST PER ERA 566546-14 AFTER ACCOMPLISHMENT OF SECTION I PERMANENT REPAIR ASSOCIATED ER/A 95-566546 ADDED FOR AC 9514. PERFORMED A GENERAL VISUAL INSPECTION REF ERA 566546-14 REV ORIGINAL. NO DEFECTS NOTED. GENERAL VISUAL INSPECTION WAS PERFORMED PER ER/A NO 566546-14 REV. ORIGINAL SECTION II AND NO FURTHER DAMAGE FOUND. OK TO CONTINUE... (LP #0455687)