What was found
SHIP 6801 FOUND CORROSION AT MID-LAV DUMP VALVE CUT-OUT. CORRECTIVE ACTION: REMOVED MID LAV DUMP VALVE ASSY TO ACCESS CORRODED AREA PER B757 AMM 38-32 (562634). C/W COMPLETION OF STEPS 1,2,3,4,5 AND 6 IAW PRI 597635-14 REV 1. TRANSFERRED TO NON-ROUTINE #1. SUMMARY OF NON-ROUTINE #1. PERFORMED ALL STEPS OF ER/A 597635-14 REV ORIGINAL. ALL RII STEPS COMPLETE. OPERATIONAL AND LEAK CHECK OF MID LAV SYSTEM COMPLETE. (8491843)