What was found
SHIP 5806 LIGHTNING STRIKE ON LAP JOINT AT STA. 540 STR. 5L. CORRECTIVE ACTION: DAMAGE REMOVED LENGTH (0.2400") DEPTH(.021") MATERIAL THICKNESS (0.080") MAX ALLOWABLE 10X (.008) FOUND TO BE OUT OF LIMITS REF. B757 SRM 53-00-01. WITHIN LIMITS PER B757-300 SRM 53-00-01-1A FIG 101 DETAIL I. PERFORMED 10X VISUAL, NO DAMAGE NOTED TREATED, PRIMED AND PAINTED AREA. (2147552)