What was found
CORROSION ON FRAME CHANNEL STA Y=908 BTW LONGERON 29 LH / 29 RHAT AFT CARGO COMPARTMENT. SUMMARY OF NRC 00079: CORROSION LEVEL 2, FRAME CHANNEL STA Y=908 BTW LONGERON 29 LH / 29 RH AT AFT CARGO COMPARTMENT WAS REPAIRED PER B717-200 SRM 53-20-07-2R PROCEDURE 3. MAINTENACE REQUIREMENTS: PERFORM A VISUAL INSPECTION , INITIAL EVERY 25,000 FLIGHT CYCLES, REPETITIVE 6,500 FLIGHT CYCLES PER B717 SRM 53- 20-07-2R-3 PARAGRAPH 6.A TABLE 205/REPAIR 3. (LP #2186831)