What was found
SHIP 5802 ( REF: N/R 13 ) AWAITING FAA APPROVAL PENDING FINALE FOR ERA 598865-14 REV. ORIG. SECTION I: PERMANENT REPAIR INSTRUCTIONS INSTALL EXTERNAL DOUBLER REPAIR. LIGHTNING STRIKE TO 4 EA FASTENERS AND SKIN STA 780 70 INCHES TO 780 80 BETWEEN STR 29L. CORRECTIVE ACTION: SUMMARY SEE NR FOR ADDITIONAL INFORMATION 002-0001:0514-2001/029 00029 COMPLIED WITH ERA 598865-14 REV. A. (2211765)