What was found
SHIP 662 FOUND CORROSION ON FLOOR FRAME AROUND NUT PLATE HOLE AT STATION 345 UNDER THE AFT GALLEY FLOOR PNL 221AF. CORRECTIVE ACTION: SUMMARY SEE NR FOR ADDITIONAL INFORMATION 002-0003:3220-9901/008 00022 EVALUATED DAMAGE AND REMOVED CORROSION AS PER 757-200 SRM 53-00-51-1A. CORROSION CONTAINED. (2260291)