What was found
TRANSFERRED FROM LOG PAGE 8626448. LT MLG FIXED STRUT O/B ATTACH AT TRUNNION FITTING CORRODED ON FWD AND AFT SIDES OF LUG. *******REFER TO NR002 AND LP#8626448**** REMOVED LUG BUSHING AND MACHINED TO REMOVE CORROSION TO 1.475. WITHIN LIMITS PER OVERHAUL MANUAL 57-40-1. INSPT LT MLG FIXED STRUT O/B ATTACH IAW B717 OHM 57-40-1 ITEM 6.C F.P.I. NO ITEMS. (QC1315) FABRICATED OVERSIZE BUSHING, C/W M.P.I OF BUSHING, AND INSTALLED BUSHING PER B717 OHM 57-40-1. (LP #2271496)