What was found
(LOG 2290830) DURING INSPECTION FOUND LH FLOOR SUPPORT SCREW HOLES (ABOVE STRINGER 25LH/RH) BETWEEN STA 400 AND 500I OF FORWARD CARGO COMPARTMENT FLOOR STRUCTURE WITH ORIGINAL THICKNESS = 0.040" AND REMAINING THICKNESS ON STATIONS BOTH SIDES (LH/RH) ON STA 500C TO 500G=0.032" THEREFORE IT'S OUT OF LIMITS. SIDE PLATE LH/RH FROM STA Y= 500C TO Y= 500I WERE REPLACED PER B737-800 SRM 51-40-02-0G PARAGRAPH 4B.