What was found
SHIP 1803 ON TAKE OFF ROLL AROUND 100 KNOTS HAD CENTER LEFT ENTRY DOOR ON EICAS AND CABIN EMERGENCY LIGHT ILLUMINATE. UNTIL LIFTOFF- IT THEN EXTINGUISHED. CORRECTIVE ACTION: T/S PER B767-400 FIM 52-71 TASK 815-807, PERFORMED BITE TEST ON PSEU, NO FAULTS. SYS DOOR TEST PASSED, NEAR AND FAR PASSED. (9183662)