What was found
AIRCRAFT 176, AFT CGO STRUCTURE SHEAR TIE CORROSION AT STA 1197+88 S36R-S37R REF TO CPCP 53-558-00. CORRECTIVE ACTION: THE CORROSION REMOVED AND THE REWORKED AREA MEASURED. THE ORIGINAL THICKNESS T=0.056". THE REMAINING THICKNESS IS 0.030". THE DEPTH OF CLEANUP IS 0.026">10%T. FOUND OUT OF LIMITS AS PER B767-300 SRM 53-00-07-1A-2 FIG101 RELEASE 119.00-06/01/22. THE NEW SHEAR TIE FABRICATED AS PER BOEING DWGING 140T2102 AND CONTROL NO 0270698948. THE SHEAR TIE REMOVED AND REPLACED AS PER B767-300 SRM 51-40-02 RELEASE 119.00-06/01/22. LP 2371725