What was found
(LOG 2382030) DURING INSPECTION FOUND CORROSION ON FLOOR BEAM AT STA 294.5 BTW LBL 11 TO RBL 35 AT W1. FLOOR BEAM AT STA 294.5 BTW RBL 23.10 TO LBL 24.53 AT W1 WAS REPAIRED PER PRI 485086-14 REV 3 AND ERA 601804-14 REV. ORIG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LOG 2382030) DURING INSPECTION FOUND CORROSION ON FLOOR BEAM AT STA 294.5 BTW LBL 11 TO RBL 35 AT W1. FLOOR BEAM AT STA 294.5 BTW RBL 23.10 TO LBL 24.53 AT W1 WAS REPAIRED PER PRI 485086-14 REV 3 AND ERA 601804-14 REV. ORIG.