As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(LOG 2393220) DURNG INSPECTION FOUND FOUND EXISTING REPAIR OVERLAPPING OUTSIDE OF THE CUTOUT AREA. REF DWG 20D52N002 REV C. COMPLIED WITH FINAL ERA 601771-14 FOR CUTOUT OF DOUBLER REPAIR OB OF STRINGERS S1L & 2 L AND STRINGERS S1R AND 2R.