REPEAT INSPECTION PER ER/A 594509-14 REQUIRED EVERY 3000FC AFTER REPAIR INSTALLATION. REPAIR IS APPLIED TO RUDDER SN 55010 INSTALLED. ASSOCIATED ER/A 00-594509 ADDED FOR AC 9503. REDEFERRED LOG TO QC, ESTABLISHED MONITOR INSP. ERA 594509-14 REV A IS NOW CURRENT. NEW FOLLOW ON ACTION IS REQUIRED. CONTINUE TO ACCOMPLISH SECTION II REPEAT INSPECTIONS EVERY 3000 CYCLES AFTER SECTION I, UNTIL COMPLETION OF SECTION III. A CCOMPLISH SECTION III AT NEXT C-CHK, NTE 02OCT2023. (LP #1969671)