What was found
(LOG 9374214) DURING INSPECTION FOUND FWD DOOR L1 EMERGENCY EXIT SIGN NEXT TO F/A SEAT INOP. REPAIRED WIRING PER ER/A 602996-14. RAN AND TERMINATED TEMPORARY WIRE TO GROUND BLOCK GD11106-DC. EMER LTS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LOG 9374214) DURING INSPECTION FOUND FWD DOOR L1 EMERGENCY EXIT SIGN NEXT TO F/A SEAT INOP. REPAIRED WIRING PER ER/A 602996-14. RAN AND TERMINATED TEMPORARY WIRE TO GROUND BLOCK GD11106-DC. EMER LTS GOOD.