DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT BS 500L BTW STRINGERS 25R TO 25L. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-40-02-0G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT BS 500L BTW STRINGERS 25R TO 25L. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-40-02-0G.