What was found
CORROSION ON FLOOR SUPPORT STA Y=180 BTW X=-9 - X=-42. CORROSION LEVEL 2. FLOOR SUPPORT WAS REPLACED IAW SRM 51-41-02-0G AND B717-200 SRM 51-41-05-0G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT STA Y=180 BTW X=-9 - X=-42. CORROSION LEVEL 2. FLOOR SUPPORT WAS REPLACED IAW SRM 51-41-02-0G AND B717-200 SRM 51-41-05-0G.