What was found
WHILE ACCOMPLISHING LT FR. 68 INSPECTION FOUND REPAIRS THAT COULD INHIBIT HFEC IN THAT AREA "WC 5311-01244-01B, SB A320-53- 1491 RO, EASA PAD 21-090" CONTACTING ENGINEERING TO SEE IF ALTERNATE INSPECTION INSTRUCTIONS ARE REQUIRED. CORRECTIVE ACTION: SUBMITTED SDR AS REQUIRED. (2543770)