What was found
DURING TAP-TEST INSPECTION OF DENTS AT RHS FWD MOVABLE VANE, A DISBONDED AREA OF 4.750 IN LENGTH AND 2.000 IN WIDTH WAS FOUND ON THE RUB STRIP. RT FWD MOVABLE VANE WAS REPAIRED IAW SRM 51-70-02-0G PAR. 15, 17A, AND SRM 57-53-01-2R-1 PAR. 4 D.