What was found
FOUND DELAMINATION ON THE LEADING EDGE END BETWEEN ES 163.740 AND ES 175.980 OF THE LT ELEVATOR LOWER PANEL DEMENSION APPROX 2 INCH*1.5 INCH AND 1 INCH FROM FS 175.980. DAMAGED AREA REPAIRED IAW SRM 55-20-01-2R-1 & SRM 51-70-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND DELAMINATION ON THE LEADING EDGE END BETWEEN ES 163.740 AND ES 175.980 OF THE LT ELEVATOR LOWER PANEL DEMENSION APPROX 2 INCH*1.5 INCH AND 1 INCH FROM FS 175.980. DAMAGED AREA REPAIRED IAW SRM 55-20-01-2R-1 & SRM 51-70-04.