What was found
CORROSION FLOOR BEAM +Y1292 LOCATED BTW FR16 TO FR20 AT FWD GALLEY AREA. RESTORED SURFACE PROTECTION O THE REWORKED AREA AS PER A319 SRM 51-75-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FLOOR BEAM +Y1292 LOCATED BTW FR16 TO FR20 AT FWD GALLEY AREA. RESTORED SURFACE PROTECTION O THE REWORKED AREA AS PER A319 SRM 51-75-12.