What was found
CRACK SHEAR PLATE STR 23 L LOCATED BETWEEN FR69 TO FR70 AT AFT GALLEY AREA. REPLACED SHEAR PLATE STR 23 L LOC. BTW FR69 TO FR70 AT AFT GALLEY AREA AS PER A321 SRM 51-42-11; SRM 51-72-11; DWG D53474180; ISSUE:Z; RELEASE DATE 14-JUL-22 AND DWG 92493544; ISSUE:AE; RELEASE DATE:19 OCT 22. MEASURE OF CRACK IS: 1.763 INCH. TOOL USED: ELECTRONIC CALIPER; PN: 500-196-30; SN: A21125629; DUE DATE: 05 NOV 23. RII INSPECTION COMPLETE 0831911. JOB COMPLETE. (LP# 2576068)