What was found
DURING INSPECTION FOUND BROKEN PROXIMITY LIGHT RED ON GALLEY 2 (AISLE SIDE). PROXIMITY LIGHT RED ON GALLEY 2 WAS REPLACED PER AMM 33-51-14 . TEST WAS PERFORMED AT NEW PROXIMITY LIGHT RED ON GALLEY 2 PER AMM 33-51-14-960-802 . TEST OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND BROKEN PROXIMITY LIGHT RED ON GALLEY 2 (AISLE SIDE). PROXIMITY LIGHT RED ON GALLEY 2 WAS REPLACED PER AMM 33-51-14 . TEST WAS PERFORMED AT NEW PROXIMITY LIGHT RED ON GALLEY 2 PER AMM 33-51-14-960-802 . TEST OK.