What was found
ON FINAL DECENT, LIGHT ACRID ODOR AFTER BLOCK-IN. STATUS MSG SMOKE, CAB TEMP & EPGS. CHECKED OVERHEAD LIGHTS & BALLASTS, PASSENGER READING LIGHTS & PSU LIGHTS, IFE EQUIPMENT & POWER OUTLETS, GALLEY OVENS & COFFEEMAKERS, WIRING VISIBLE IN THE AREA REPORTED. NO DISCREPENCIES NOTED. RAN BOTH ENGINES WITH PACKS RUNNING CABIN FANS ON & OFF, NO SMOKE OR ODOR. ALSO CHECKED E/E COMPARTMENT, NTF. SMOKE, CAB TEMP, EPGS, CLASS II MESSAGES, UNRELATED, REVIEWED OIL CONSUMPTION TRENDS, NORMAL. NO FAULTS NOTED.