As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SHIP 5811 AD RELATED: INITIAL INSPECTION: GIRT BAR LEAF SPRINGS 2 E/A DOES NOT RETAIN THE SLIDERS OF R2 DOOR (NEED REPLACE GIRT BAR PER AMM 25-66-10-201 AND PERFORM CARD INSTRUCTIONS. CORRECTIVE ACTION: SUMMARY OF NRC 00057: GIRT BAR WAS REPLACED PER B757-300 AMM 25- 66-10 AND CARD INSTRUCTIONS STEP 11,12,13 AND 14 WAS PERFORMED TEST OK. (2591841)