What was found
SHIP 1200 HFEC INSPECTION FOUND 01 EA CRACK ON STRINGER S-2R AT STA 717 BETWEEN TWO FASTENERS HOLE AND IT IS ABOUT 1 INCH LONG. CORRECTIVE ACTION: DAMAGE AREA REPAIRED PER PRI 605516-14 (2619863)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHIP 1200 HFEC INSPECTION FOUND 01 EA CRACK ON STRINGER S-2R AT STA 717 BETWEEN TWO FASTENERS HOLE AND IT IS ABOUT 1 INCH LONG. CORRECTIVE ACTION: DAMAGE AREA REPAIRED PER PRI 605516-14 (2619863)