What was found
SHIP 3509 -DIV- DIVERSION TO MSP DUE TO ENGINE 2 STATOR ANTI-ICE VALVE CLOSED MESSAGE, UNABLE TO CONTINUE DUE TO MESSAGE REMOVES THE ETOPS ALTERNATE AIRPORTS DUE TO ICING CONDITIONS. CORRECTIVE ACTION- T/S PER A350TSM, FOUND MULTIPLE RIGHT ENGINE EEC FAULTS. REPLACED EEC PER A350AMM, RIGHT ENGINE OPERATIONAL CHECK NORMAL. LP9558430, 2620914