What was found
SHIP 3409 DURING SVC CK FOUND EMER LIGHTS OUT AT SEATS 45-47HJ 51-53HJ AND 56-57HJ. CORRECTIVE ACTION: CIDS 1 EPSU TEST SHOWS EPSU (18WL) DOOR 4 FAULT, BITE TEST AT CONTROLLER SHOWS UNIT FAULT. NEW CONTROLLER WAS SLAVED IN AND IT ALSO SHOWS SAME FAULT. CHECKED CONNECTORS 5450VC: 48, 42, 38 NO DEFECTS NOTED. R/R EPSU 18WL AGAIN PER A330 AMM 33-52. OPS OK. (9930051)