What was found
(LOG 2701778) DURING INSPECTION FOUND FLOOR BEAM STA 328 IS CORRODED AROUND NUTPLATE HOLES RBL 15 TO RBL 55. REPAIRED FLOOR BEAM STA328 RBL15 TO RBL55 IAW DELTA ERA 606989-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(LOG 2701778) DURING INSPECTION FOUND FLOOR BEAM STA 328 IS CORRODED AROUND NUTPLATE HOLES RBL 15 TO RBL 55. REPAIRED FLOOR BEAM STA328 RBL15 TO RBL55 IAW DELTA ERA 606989-14.