What was found
SHIP 3354 DURING H CHECK, WHILE EXECUTION OF JIC 5330-01152 REGARDING LATERAL PANEL MODIFICATION FR84-85 (-02A LHS AND -02B RHS) AND LATERAL PANEL MODIFICATION FR86-87 (-03A LHS AND -03B RHS), EDGE MARGIN COULD NOT BE FULFILLED AS PER JIC REQUIREMENTS. CORRECTIVE ACTION: REF ER/A 606974-14. (2715071)