What was found
SHIP 3354 CONFIRM DT EVALUATION FOR POSSIBLE FCS REPAIR INTERNAL STRUCTURE MODIFICATION DOUBLER AT FRAME 86 , STR 5AL IN UPPER FUSELAGE. CORRECTIVE ACTION: COMPLIED WITH PRI 606202-14, VALIDATED ER/A 606202-14 MATCHES PRI 606202-14. (2716235)