What was found
SHIP 3354 CONFIRM DT EVALUATION FOR POSSIBLE FCS REPAIR INTERNAL STRUCTURE DOUBLER AT FR86,STR2BR IN UPPER FUSELAGE. CORRECTIVE ACTION: COMPLIED WITH PRI 606202-14 REV. 0, VALIDATED ER/A 606202-14, EXISTING MODIFICATION INSTALLED AS PER EM 5330-01151-05B. MODIFICATION IS APPROVED AS PER FAA AD 2015-23-06. ADDITIONALLY DEVIATION FOR SHORT EDGE MARGIN WERE APPROVED AS PER DELTA ER/A543321-14AD. (2716670)