What was found
SHIP 3354 CONFIRM DT EVALUATION FOR POSSIBLE FCS REPAIR INTERNAL STRUCTURE DOUBL ER AT FR86, STR2BL IN UPPER FUSELAGE. CORRECTIVE ACTION: COMPLIED WITH PRI 606202-14 REV. 0, VALIDATED ER/A 606202-14 REV. EXISTING MODIFICATIOINSTALLED AS PER EM 5330-01151-05B. ADDITIONALLY , DEVIATIONS FOR SHORT EDGE MARGINS WERE APPROVEDAS PER DELTA ERA 543310-14AD BY MEANS OF APPROVAL ALREADY CONTAINED IN INSTRUCTIONS OF AIRBUS SB. (2716819)