As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SHIP 5651 MAIN CABIN FLOOR STRUCTURE FLOOR PANEL SUPPORT STRUCTURE IS CORRODED AREA BELOW THE RH AFT E&E DOOR AREA APPROX AT STA 1040. CORRECTIVE ACTION: REMOVED CORROSION ON FLOOR STA 1040.0, OUT OF LIMITS IAW B757 SRM 53-40-13. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM AND RESTORED SURFACE PROTECTION IAW B757 AMM 51-21. (2747984)