What was found
SHIP 5803 R CTR ENT DOOR ILLUM IN FLIGHT. PRESSURIZATION WAS GOOD. CORRECTIVE ACTION: REMOVED AND INSTALLED NO 2 PASSENGER DOOR WARNING SENSOR S10091 REF B757 AMM 52-71-00. TEST OK (4054634)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHIP 5803 R CTR ENT DOOR ILLUM IN FLIGHT. PRESSURIZATION WAS GOOD. CORRECTIVE ACTION: REMOVED AND INSTALLED NO 2 PASSENGER DOOR WARNING SENSOR S10091 REF B757 AMM 52-71-00. TEST OK (4054634)