What was found
CORROSION ON FLOOR SUPPORT STA Y=200 X=10 AT PAX CABIN W1. SUMMARY OF NRC 00275: CORROSION LEVEL 2. FLOOR SUPPORT STA Y=200 X=10 WAS REPLACED PER B717 SRM 51-41-05-0G. (LP #2821504)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT STA Y=200 X=10 AT PAX CABIN W1. SUMMARY OF NRC 00275: CORROSION LEVEL 2. FLOOR SUPPORT STA Y=200 X=10 WAS REPLACED PER B717 SRM 51-41-05-0G. (LP #2821504)