As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FLOOR SUPPORTS STA Y=197 AND BTW LBL=15/43 WAS FOUND OUT LIMITS AT PAX CABIN (W1). SUMMARY OF NRC 00677: CORROSION LEVEL 2. FLOOR SUPPORT STA Y=197 BTW LBL=15/43 WAS FABRICATED AND REPLACED PER DWG 99365534 REV BW AND B717-200 SRM 51-41-02-0G AND 51-41-05-0G. (LP #2850635)