What was found
CORROSION AT ANGLES (2 EA) WAS FOUND DURING DOOR JAMB DISASSEMBLY. SUMMARY OF NRC 00196: CORROSION LEVEL 2. ANGLES (2 EA) WERE FABRICATED AND INSTALLED PER B717-200 SRM 53-20-15-2R PROCEDURE 7 REPAIR 7 AND 51-41-05-0G. (LP #2886801)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AT ANGLES (2 EA) WAS FOUND DURING DOOR JAMB DISASSEMBLY. SUMMARY OF NRC 00196: CORROSION LEVEL 2. ANGLES (2 EA) WERE FABRICATED AND INSTALLED PER B717-200 SRM 53-20-15-2R PROCEDURE 7 REPAIR 7 AND 51-41-05-0G. (LP #2886801)