What was found
CORROSION WAS FOUND ALONG FRAME SPLICE REPAIR AT STA 927 BTW L26-L AND L26-R. SUMMARY OF NRC 00560: CORROSION LEVEL 2. FRAME SPLICE REPAIR AT STA 927 BTW L26-L AND L26-R WERE FABRICATED AND REPLACED PER B717-200 SRM 53-20-07-2R PROCEDURE 3 PAR 5, 51- 41-02-0G, 51-41-05-0G AND PER 53-20-07-2R PROCEDURE 3 PAR. 6, THE REPAIR'S SPECIFIED MAINTENANCE REQUIREMENTS ARE A VISUAL INSPECTION INITIALLY WITHIN 25,000 CYCLES AFTER INSTALLATION WITH REPETITIVE INTERVAL OF 6,500 CYCLES. (LP #2891710)