What was found
CORROSION OUT OF LIMITS AT CUSP WEB STA X=60 BTW STA Y=375 TO STA Y=380 AND STA Y=797 TO STA Y=802 LH SIDE PAX CABIN IN REFERENCE NRC 0323. SUMMARY OF NRC 00439: CORROSION LEVEL 2. WEB STA X=60 BTW STA Y=375 TO STA Y=380 AND STA Y=797 TO STA Y=802 LH WAS REPAIRED PER B717 SRM 53-00-55-2R PROCEDURE 4 FIG. 203 AND FIG. 207. (LP #2937062)