As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FLOOR SUPPORT Y=180 FROM X=-10 TO X=-43, FROM Y=162 TO Y=198 X=-45 AT W-1 AREA CPAX IN REF NRC 00541. SUMMARY OF NRC 00610: CORROSION LEVEL 2. FLOOR SUPPORTS Y=180 FROM X=-10 TO X=-43 AND FLOOR SUPPORT FROM Y=162 TO Y=198 X=-45 AT W-1 AREA CPAX WERE FABRICATED AND REPLACED PER B717-200 SRM 51-41-02-0G. (LP #2987467)