What was found
SHIP 0695 AFTER CARGO COMPARTMENT, BETWEEN STA 1500 AND 1520, FLOOR PANEL SUPPORTS, WITH CORROSION ON SEVERAL POINTS. CORRECTIVE ACTION: INTERCOSTAL WAS EVALUATED AND FOUND OUT OF LIMITS, IT WAS MANUFACTURED ACORDING TO THE DRAWING, THERMAL AND CHEMICAL TREATMENT WAS GIVEN. PRIMER AND PAINT WERE APPLIED, INTERCOSTAL WAS INSTALLED. I.A.W. B 757-200 DRAWING CMA- 23-0134-01B DRAWING 146N5451. (2992107)