What was found
THE EMERGENCY LIGHTS DON'T OPERATE CORRECTLY DURING SERVICE CHECKS. SUMMARY OF NRC 00700: DURING CONTINUITY AND VOLTAGE CHECK TERMINAL 10, 11, AND 12 ON S3-559 WERE FOUND WITH CONTINUITY BETWEEN THEM. TERMINAL 10, 11, AND 12 ON S3-559 WERE INSTALLED CORRECTLY PER B717 WDM 33-51-11. EMERGENCY LIGHT BATTERY ASSEMBLY WAS REPLACED PER B717 AMM 33-51-04. OPERATIONAL TEST OF THE EMERGENCY LIGHTING SYSTEM WAS PERFORMED PER B717 AMM 33-51-00 710-801. TEST OK. (LP #0017539)