What was found
CORROSION ON CABIN FLOOR SUPPORTS (2 EA) STA Y=200, BTW X=7/-7, AND BTW X=-45.5/-56.5 (OUT OF LIMITS). SUMMARY OF NRC 00412: CORROSION LEVEL 2. FLOOR SUPPORTS (2 EA) STA Y=200, BTW X=7/-7, AND BTW X=-45.5/-56.5 WERE FABRICATED PER B717 DWG 9936534 REV BW AND REPLACED PER B717-200 SRM 51-41-02-0G AND 51-41-05-0G. (LP #0071557)