What was found
SHIP 6813A.A EXISTING REPAIR WAS FOUND IN THE INSPECTION AREA STA 1460 BTW S-25L TO S-27L. CONTACT LIAISON ENGINEERING FOR REQUIRED ACTIONS FOR THE REPAIRED AREA PRIOR TO FURTHER FLIGHT IN REF. TO AMDS 5311-01227-01A STEP 2. CORRECTIVE ACTION: SUMMARY OF NRC 00170: PERMANENT REPAIR WAS PERFORMED ON FRAME SECTION ON STA 1460 BTW S-24L TO S-24L. PER ER/A 613990-14AD REV ORG. SECTION I AND PRI 613990-14 AD REV 1. (0098330)