As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON DOOR CLOSURE AT BLOCKOUT, GATE AGENT FOUND BOTTOM OF DOOR 01L BENT, BOTTOM RIGHT. MAINTENANCE INSPECTED 1L DOOR AND FOUND AFT LOWER EDGE FLANGE RADIUS BENT OUT. PERFORMED REPAIR 3 - DOOR EDGE FLANGE REPAIRS PER SRM 52-00-00-2R PROCEDURE 3. WAS ABLE TO WORK EDGE STRAIGHT. NO CRACKS OR PULLED RIVETS NOTED. NO OTHER DEFECTS PRESENT. (LP #5495776)