What was found
SHIP 3228 DISC: WATER AND WASTE INDICATION ON FAP PANEL FLASHING FORWARD ATTENDANT PANEL. C/A: MEL NUMBER ADDED FOR DISPATCH. BITE TEST AND GRD TEST ON CIDS DIR 1 FAULTED DEU A 200RH12. ALSO FOUND SOME EMER EXIT LIGHTS WERE MALFUNTIONING AND CIDS CAUTION LIGHT ON FAP. R/R DEU A 200RH12. ALL BITES TEST OK. NO FAULTS AT THIS TIME. MEL AND PLACARD REMOVED.