What was found
CRACK INTERCOSTAL AT X=0, BTWEEN STA Y=1002 TO Y=1022, CABIN FLOOR SUPPORT STRUCTURE. SUMMARY OF NRC 00511: TRIMMED OUT INTERCOSTAL AT X=0, BT STA Y=1002 TO STA Y =1022 WAS REPAIRED PER B717-200 SRM-51-70-11-2R PROCEDURE 1 REPAIR. (LP #0156032)